The E-PUMP is an electric condensate recovery pump unit: a receiver with a level-controlled pump that returns condensate to the boiler feed tank or deaerator. Where the condensate load is large and the discharge is continuous, an electric pump is the more economical option.
The receiver cools the condensate slightly before pumping, which is what allows an electric pump to run without cavitation – the condensate is no longer at saturation temperature when it reaches the impeller.
Design and construction
Steel receiver with level controls, one or two centrifugal pumps and a control panel that starts and stops the pump on level. The packaged arrangement includes the suction piping, non-return valves and isolation valves needed to commission the unit.
Key features
- High flow capacity for large condensate loads
- Level-controlled automatic operation
- Receiver design prevents pump cavitation
- Packaged unit with panel and valves
- Duplex pump option for continuity
- Returns water, chemicals and heat to the boiler house
Selection and sizing
Size on the peak condensate flow and the total head to the feed tank, allowing for the receiver height and any pressure in the return system. Confirm the electrical supply and area classification, and whether a standby pump is required for a critical plant.
Installation and maintenance
Set the receiver at the low point of the drainage system, with vented gravity feed and an overflow to drain. Provide a stable foundation for the pump set, wire the level controls to the panel, and commission the pumps against a closed valve before opening to the return line.
Options and spare parts
Pump seals, impellers, level controls and panel components are available as spares.