The BSA3T is a bellows sealed stop valve for steam, compressed air and general process fluids. The bellows contains the fluid at the stem, so the valve can be used on lines where a packed gland would leak, seize or require routine attention.
It is a common choice on utility isolation points where the medium changes between steam, air and water, and where one valve standard is preferred across the plant.
Design and construction
Body with a stainless steel bellows, lapped seat and plug, and a stem guided to keep the plug centred through repeated cycling. The bellows is welded at both ends so that the only seal in the valve is metal.
Key features
- Gland-free – suitable for steam, air and process fluids
- Tight closure with a lapped seat
- Repeatable operation over many cycles
- Stainless steel bellows and trim
- Back-up secondary seal
- Simple maintenance – the bellows is the only wearing seal
Selection and sizing
Confirm the medium: bellows valves suit clean fluids, and are not recommended for slurries or fluids that can crystallise in the bellows convolutions. State the pressure class and connection standard for the pipe class.
Installation and maintenance
Install in the direction of flow with access to the handwheel. Do not throttle with the valve; use it for isolation only. On air service, check for internal leakage at the seat after commissioning.
Options and spare parts
Bellows assemblies, plugs, seats and gaskets are available.