The BSA1T is a bellows sealed stop valve for steam and condensate isolation. The bellows replaces the gland packing, so the valve does not leak at the stem and needs no routine gland maintenance – the two problems that most often force a shutdown on a steam isolation valve.
It is the standard isolation valve for traps, strainers, separators, control valves and equipment connections on saturated steam and condensate lines.
Design and construction
Cast or ductile iron body with a stainless steel bellows, a lapped seat and a rising stem with a position indicator. The bellows is welded to the stem and body so the process fluid is fully contained, and a secondary seal backs up the bellows.
Key features
- Bellows sealed – no stem leak, no gland to maintain
- Tight shut-off for isolation of traps and equipment
- Rising stem with visual position indication
- Stainless steel bellows for saturated steam duty
- Secondary back-up seal
- Suitable for condensate and hot water as well as steam
Selection and sizing
Confirm size, pressure class and temperature, and specify whether a rising or non-rising stem is required for the installation. Bellows valves are isolation valves: if the duty needs throttling, use a control valve or a globe valve designed for it.
Installation and maintenance
Install with flow in the direction of the arrow, allow access for the handwheel and leave room for the stem to rise. Do not over-torque on closing – the seat is lapped and tight closure needs only firm effort.
Options and spare parts
Bellows assemblies, seats, plugs and gaskets are available for all sizes.