TVA steam flowmeter for large steam mains and plant energy monitoring

TVA Steam Flowmeter

Steam flowmeter for large mains and plant-wide energy monitoring

The TVA is a steam flowmeter for larger mains and plant-wide metering. Where the TFA covers process-level measurement, the TVA is specified on the main headers and boiler outlets where the flow is high and the pipe size is large.

Metering the main tells a plant how much steam it actually produces and distributes, which is the baseline for every efficiency project and for verifying that a leak-repair programme has delivered savings.

Design and construction

Flow element and transmitter configured for large pipe sizes and high mass flow, with pressure and temperature compensation to report mass flow. The installation arrangement is designed to keep the straight-run requirement achievable in a plant room.

Key features

  • Designed for large steam mains and high mass flows
  • Mass flow with pressure/temperature compensation
  • Digital output for energy management systems
  • Wide turndown across seasonal load changes
  • Suitable for saturated and superheated steam
  • Verifies savings from steam system improvements

Selection and sizing

Supply the maximum and normal flow, the pressure and temperature, and the pipe schedule. For mains with strongly seasonal loads, check the turndown at the minimum flow, and consider a second smaller meter for low-load periods if accuracy matters.

Installation and maintenance

Provide the specified straight lengths, with the pressure and temperature tappings at the correct positions. Insulate the pipework, and keep the transmitter dry and accessible for calibration.

Options and spare parts

Transmitters, sensing elements and gaskets are available; calibration certificates are supplied with each meter.

Request a Quote

Technical Specifications

Standard configurations. Custom materials, connections and special testing available on request.

ParameterSpecification
Product type Steam mass flowmeter, large bore
Size range DN50 - DN300
Connections Flanged EN 1092 PN16 / PN25 / PN40
Media Saturated and superheated steam
Output 4-20 mA / digital, with compensation inputs
Max operating pressure (PMA) 40 bar g
Max operating temperature (TMA) 400 °C
Documentation Calibration certificate, material certificate

Typical Applications

Energy Monitoring

Steam, water and compressed air flow measurement for energy accounting and cost allocation.

Process Optimisation

Accurate flow data to tune boilers, processes and utilities for maximum efficiency.