Fig 33 Y-type strainer with finer screen for steam trap and instrument protection

Fig 33 Y-Type Strainer

Y-type strainer with fine screen - protects trap orifices, meters and instruments

The Fig 33 is a Y-type strainer fitted with a finer screen than the general-purpose Fig 12, for duties where small particles matter: trap orifices, steam meters, positioners and small control valves.

Where a coarse strainer protects a line from debris, a fine strainer protects a mechanism. The Fig 33 is the specification when the downstream device has small clearances or narrow passages.

Design and construction

Y-pattern body with a fine mesh screen in stainless steel, a blowdown plug and a screen that can be removed for cleaning. The finer mesh increases pressure loss slightly, which is accounted for in sizing.

Key features

  • Fine mesh screen for small-particle protection
  • Replaceable screen in stainless steel
  • Blowdown plug for in-line cleaning
  • Protects trap orifices, meters and instruments
  • Screwed or flanged connections
  • Suitable for steam, condensate, water and air

Selection and sizing

Specify the mesh required by the downstream device – a trap orifice or a meter usually calls for a finer screen than a general line. Check the pressure loss at design flow, since a fine screen costs more pressure than a coarse one.

Installation and maintenance

Install immediately upstream of the protected device with the screen leg down. Blow down at the recommended interval, and renew the screen when it is damaged or permanently clogged.

Options and spare parts

Fine mesh screens, gaskets and blowdown plugs are available.

Request a Quote

Technical Specifications

Standard configurations. Custom materials, connections and special testing available on request.

ParameterSpecification
Product type Y-type strainer, fine screen
Size range DN15 - DN50 (1/2" - 2")
Connections Screwed BSP/NPT or flanged EN 1092 PN16
Body material Cast iron / ductile iron / stainless steel
Screen Stainless steel fine mesh, replaceable
Max operating pressure (PMA) 16 bar g
Max operating temperature (TMA) 250 °C
Testing Shell test to EN 12266

Typical Applications

Steam & Process Isolation

Bellows sealed stop valves, ball valves and check valves for tight, maintenance-free isolation.

Steam Quality

Separators, strainers, air vents and vacuum breakers protecting plant and improving steam quality.

Utilities & Water

Pipeline ancillaries for compressed air, water and general industrial service.