The AE30 is an automatic air vent for liquid and steam systems. A thermostatic capsule opens the vent port whenever air or a non-condensable gas reaches it and closes it on contact with condensate or water, so air is removed continuously without losing fluid.
Air in a steam system is expensive: it sits on heat transfer surfaces, holds back condensate, causes corrosion and produces the cold spots that lead to a call-out. An air vent at the high point of the equipment is the cheapest way to prevent all four.
Design and construction
Sealed thermostatic capsule in a small stainless or brass body with a vent orifice. The capsule responds to temperature – air and gas are cooler than steam, so the port opens; steam or hot condensate closes it within a few degrees.
Key features
- Continuous automatic removal of air and non-condensable gases
- Thermostatic capsule with no external power or signal
- Closes on steam or hot liquid, so no fluid loss in normal running
- Small, robust body for high-point installation
- Protects heat transfer surfaces from air blanketing
- Reduces corrosion and cold-start time
Selection and sizing
Fit one at every high point: the top of a heat exchanger, the end of a steam main, above a jacketed vessel and on any equipment that starts flooded with air. Choose the capsule with regard to the working pressure and temperature, and confirm the body material for the medium.
Installation and maintenance
Mount at the highest point of the equipment, vertically, with the vent port clear and a short discharge pipe if the vent is indoors. Do not install below a water level or where it will be flooded with condensate, and check it is not isolated by a closed valve upstream.
Options and spare parts
Replacement thermostatic capsules and body gaskets are available; the capsule is the only part that normally needs renewal.