The TD16 / TD16F thermodynamic steam trap is the workhorse disc trap for steam distribution. Condensate entering the trap flashes as it passes the disc, and the resulting high-velocity mixture closes the disc on a cushion of flash steam. The result is discharge at steam temperature, tight closure on live steam, and a trap that keeps working in frost, vibration and water hammer.
The TD16F variant adds an integral strainer, which is the usual specification for mains and tracing where dirt from new pipework is expected.
Design and construction
Stainless steel body with a hardened disc as the only moving part, and a seating face that is lapped for tight shut-off. The F version carries a built-in screen ahead of the disc so scale and weld slag cannot damage the seating area.
Key features
- Disc-only mechanism – no float, lever or bellows to fail
- Freeze-proof construction for outdoor and tracing duty
- Discharges condensate at close to steam temperature
- Withstands water hammer, vibration and superheat
- TD16F adds an integral strainer for dirty pipework
- Compact body that fits readily into lagged mains
Selection and sizing
Apply TD16/TD16F to steam mains, drip legs, tracing lines, unit heaters and outdoor pipework. Check the back pressure ratio: a disc trap needs the downstream pressure to stay below roughly 80 percent of the upstream pressure, so a high lift into the return main calls for a different trap type. For large condensate loads choose a float trap instead.
Installation and maintenance
Fit horizontally or with flow downwards, at the low point or end of the main. Leave the discharge pipe free to drain and avoid a long vertical lift after the trap. Where traps discharge into a common manifold, fit individual non-return valves to stop backflow.
Options and spare parts
Discs, strainer screens and gaskets are the routine spares; bodies are normally retained for the life of the plant.